6层板的绝缘耐压问题
(
2022-07-24
阅读 1959
)
阅读
1959
(0)
(2)
精选留言
写留言
用户( 3***2A )
(0)
好的,谢谢了。
张**( 5***5G )
(0)
您好,FR4的耐压各层间的耐压参数,就是30KV/MM,是多少厚度就按这个去折算(考虑到实际生产过程中厚度公差+/-10%的原因,一般的0.1mm耐压2700Vj是可以的)
询价下单交货开票需要协助的可以点击下单主界面左上方“人工客服”图标-“PCB/钢网/SMT业务咨询”,找到您的服务专员联系处理。谢谢!
<style> @font-face{ font-family:"Times New Roman"; } @font-face{ font-family:"宋体"; } @font-face{ font-family:"Calibri"; } p.MsoNormal{ mso-style-name:正文; mso-style-parent:""; margin:0pt; margin-bottom:.0001pt; mso-pagination:none; text-align:justify; text-justify:inter-ideograph; font-family:Calibri; mso-fareast-font-family:宋体; mso-bidi-font-family:'Times New Roman'; font-size:10.5000pt; mso-font-kerning:1.0000pt; } span.msoIns{ mso-style-type:export-only; mso-style-name:""; text-decoration:underline; text-underline:single; color:blue; } span.msoDel{ mso-style-type:export-only; mso-style-name:""; text-decoration:line-through; color:red; } @page{mso-page-border-surround-header:no; mso-page-border-surround-footer:no;}@page Section0{ } div.Section0{page:Section0;}</style>
成品板厚2mm,按照嘉立创的层压结构制作6层板(即顶层线路1和中间线路2之间采用0.1mm的2313 PP布压合,中间线路3和中间线路4之间采用0.2mm的7628 PP布压合,中间线路5和底层线路6之间采用0.1mm的2313 PP布压合)。我想咨询的是:顶层线路1和中间线路2之间耐压多少?中间线路3和中间线路4之间耐压多少?中间线路5和底层线路6之间耐压多少?因为实际设计项目中,其中有5层有400V高压在走,其中中间有一层低压在走,而且,高低压之间要打2000V耐压,我需要评估耐压情况,或者这种设计方案/方式是否可行?事情紧急,还请嘉立创的专家尽快回复,万分感谢。